Skip to tool
ecech.
🌐 Network & IP

Convert DSCP Values into Decimal, Binary and ToS Bytes

Translate a six-bit DSCP codepoint into packet-header representations.

0–63

Shifted ToS byte

DSCP binary digits

ToS byte hexadecimal value

DSCP class selector

Advertisement

How the calculation works

Inputs1 visible fieldsRuleConverterPrimary outputShifted ToS byte

How to Use This Tool

Translate a six-bit DSCP codepoint into packet-header representations. Convert a DSCP decimal codepoint into six-bit binary, shifted ToS byte value and hexadecimal byte with ECN set to zero.

The decision this tool supports

Device interfaces alternately request a DSCP codepoint, binary field or full eight-bit ToS value, inviting a two-bit shift error. This page keeps the decision bounded to shifted tos byte and the supporting outputs shown beside it. DSCP Value Format does not import an account, infer a market rate, or silently substitute an industry average.

Measured inputsNamed formulaDecision outputs
DSCP 46 is binary 101110 and shifts to ToS byte 184 (hex B8) when ECN is zero.

Inputs and units

The DSCP Value Format calculation uses DSCP decimal value. Keep all money values in one currency and all time, distance, mass, energy or volume entries in the unit printed beside the field. Mixing DSCP Value Format scopes can produce a plausible number with the wrong meaning.

  • DSCP decimal value is entered in 0–63.

Formula and worked check

The six-bit DSCP codepoint occupies the high six bits of the traffic-class byte; with ECN 00, the byte value is DSCP × 4. DSCP 46 is binary 101110 and shifts to ToS byte 184 (hex B8) when ECN is zero. The DSCP Value Format default is an executable known-answer case, not a benchmark or recommendation. Change one input and verify that the direction of shifted tos byte still matches the stated relationship.

How to interpret the result

The decimal ToS output assumes ECN bits are zero; represent the same byte in hexadecimal when a configuration expects that notation. The additional DSCP Value Format outputs expose the denominator, comparison, capacity or reverse value needed to audit the primary result instead of presenting one unexplained number.

Assumptions

  • The input is an integer from 0 through 63.
  • ECN bits are set to binary 00.
  • Class selector is shown as floor(DSCP ÷ 8), not a PHB name.

Save the DSCP Value Format input values and date with any material decision. A later DSCP Value Format rerun is reproducible only when the same assumptions and units are available.

Limitations and safety boundary

It assumes ECN is zero and does not validate vendor-specific command syntax or traffic-class handling. DSCP Value Format is an estimate and cannot replace a contract, local code, licensed professional, calibrated measurement, lender statement or platform report where one governs the decision.

Source and privacy

The DSCP Value Format definition or rule was checked against IANA Differentiated Services Field Codepoints on 2026-08-26. Recheck IANA Differentiated Services Field Codepoints when a specification or policy behind DSCP Value Format can change. DSCP Value Format arithmetic runs in this browser tab; ecech does not receive the values through a calculation API.

Sources & assumptions

Tool Spec v2 · verified 2026-08-26. Platform rules and fees can change; the editable inputs remain authoritative for your account.

Official references

Model assumptions

  • The input is an integer from 0 through 63.
  • ECN bits are set to binary 00.
  • Class selector is shown as floor(DSCP ÷ 8), not a PHB name.
  • It assumes ECN is zero and does not validate vendor-specific command syntax or traffic-class handling.
Advertisement

Frequently Asked Questions

What does DSCP Value Format calculate?
It calculates shifted tos byte, dscp binary digits, tos byte hexadecimal value, dscp class selector from dscp decimal value using the displayed formula.
What known result verifies DSCP Value Format?
DSCP 46 is binary 101110 and shifts to ToS byte 184 (hex B8) when ECN is zero.
Which assumption matters most?
The input is an integer from 0 through 63.
When should I reject the result?
It assumes ECN is zero and does not validate vendor-specific command syntax or traffic-class handling.
Which source supports the calculation?
The recorded source is IANA Differentiated Services Field Codepoints, reviewed 2026-08-26. User-specific inputs still come from the user's own records.
Does DSCP Value Format send my values to a server?
No ecech calculation API receives values entered into DSCP Value Format; its arithmetic runs in browser JavaScript.

What people usually need next

Picked by hand, not by algorithm.

Related tools in Network & IP

Browse all Network & IP tools
The person who builds ecech., at the desk where the tools are written.

Made by one person

ecech. is not a content farm. Every tool here is written and checked by hand, one at a time, by someone who wanted the tool to exist and could not find a version that showed its working.

No accounts and no sign-in, and nothing you type reaches a server — every calculation on this page runs inside your browser. The ads are served by Google and do set their own cookies, which is set out in full on the privacy page. More about the site.